Wastewater Treatment Plant Sodium Hypochlorite Generator Electrolytic Cell

Product Details
Customization: Available
After-sales Service: on Site Technical Support
Warranty: 1 Year
Still deciding? Get samples of $ !
Request Sample
Diamond Member Since 2025

Suppliers with verified business licenses

Registered Capital
2000000 RMB
  • Wastewater Treatment Plant Sodium Hypochlorite Generator Electrolytic Cell
  • Wastewater Treatment Plant Sodium Hypochlorite Generator Electrolytic Cell
  • Wastewater Treatment Plant Sodium Hypochlorite Generator Electrolytic Cell
  • Wastewater Treatment Plant Sodium Hypochlorite Generator Electrolytic Cell
  • Wastewater Treatment Plant Sodium Hypochlorite Generator Electrolytic Cell
  • Wastewater Treatment Plant Sodium Hypochlorite Generator Electrolytic Cell
Find Similar Products

Basic Info.

Model NO.
EW-EC
Certification
CE
Application
Industries, Science, and Technology.
Voltage
220V
Disinfection Method
Electrolysis
Name
Sodium Hypochlorite Generator Electrolysis Cell
Capacity
20-500g
Transport Package
Export Standard Packaging
Origin
Hunan
HS Code
8543300090
Production Capacity
500 Sets/Month

Product Description

Factory price sodium hypochlorite generator electrolytic cell

(We can customize it according to your customization requirements)


Wastewater Treatment Plant Sodium Hypochlorite Generator Electrolytic Cell
Wastewater Treatment Plant Sodium Hypochlorite Generator Electrolytic CellWastewater Treatment Plant Sodium Hypochlorite Generator Electrolytic Cell

The electrolysis method is used to produce sodium hypochlorite, mainly by electrolyzing 2%
5% diluted salt water produces sodium hypochlorite disinfectant solution. Electrolytic reaction
It should generally be carried out in an electrolytic cell, where the saltwater solution contains
There are several ions such as NA+and H -, which act under a certain electric field
Due to the movement of ions and electrode reactions, the electrolyte solution,
At this point, negative ions such as CL - and OH - move towards the anode, while NA+
Positive ions such as H+move towards the cathode and emit on the corresponding electrode
Generate electrical discharge, thereby carrying out oxidation-reduction reactions and producing corresponding
Sodium hypochlorite strong oxidizing solution. Applied to on-site production of secondary chlorine
Sodium sulfate disinfectant and electrolysis method for treating industrial wastewater;
This method prepares sodium hypochlorite solution on site without the need to add it
He uses chemical agents to avoid using traditional chemicals as raw materials
The risk brought by materials, how much is used and how much is produced.

Wastewater Treatment Plant Sodium Hypochlorite Generator Electrolytic CellWastewater Treatment Plant Sodium Hypochlorite Generator Electrolytic CellWastewater Treatment Plant Sodium Hypochlorite Generator Electrolytic CellWastewater Treatment Plant Sodium Hypochlorite Generator Electrolytic Cell
Hunan Echwater Technology Co., Ltd. has been focusing on providing environmentally friendly water treatment solutions for
customers. -Hunan Echwater Technology Co., Ltd.- is an enterprise focusing on electrolysis equipment.

ECHWATER company focuses on core products such as acid electrolyzed water generator, hypochlorous acid generator,
sodium hypochlorite generator, acidic oxidizing potential water generator, alkaline water generator, chlorine dioxide generator,
hydrogen-rich water generator, water purifier, ozone generator, etc., which are widely used in hospitals, industries,
schools, hotels, factories, airports, homes and other fields.

Wastewater Treatment Plant Sodium Hypochlorite Generator Electrolytic Cell
Wastewater Treatment Plant Sodium Hypochlorite Generator Electrolytic Cell
FAQ

1.When will you arrange production?
In 7 workdays when we receive your advanced payment.

2. Can you customize machines according to our needs?
Yes, we can.

3. What shippment do you provide?
We can provide what it can, such as sea freight, air freight,railway freight etc. 
We can do it according to your needs.

4.  How often should the electrolytic cell be cleaned?
  • Depends on water hardness:

    Soft water: Acid wash every 6 months.
  • Hard water (>150 ppm Ca²+): Every 3 months with 10% citric acid solution."

 5. Is scaling a major issue? How do you prevent it?

  • Yes, hard water causes Ca/Mg deposits. We recommend:

    1. Pre-filtration (5μm filter).

    2. Automatic acid dosing system (optional).

    3. Anti-scaling electrodes (special MMO formulation).

Strict QC & Fast delivery
High quality goods, Perfect Pre-sales and after-sales service.
We will update you any production process after placing order.
We have special timely after-sales team to solve your problem during using our products.
Any question will be get our feedback in the first time.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier